Containment Analysis Package

CAP has been developed for analysing the thermal hydraulic behavior in the containment for postulated accident conditions and can analyze DBA (Design Basis Accident) such as LOCA (Loss of Coolant Accident) and MSLB (Main Steam Line Break).

Characteristics
Technique-independent code developed domestically Using state-of-art technique including 3-fields and 3-phases Coupling with SPACE(system code developed in Republic of Korea) Capability of both multi-dimensional and lumped parameter analysis

Applicable Fields
Design pressure/temperature
ECCS efficiency
Subcompartment
Long-term containment pressure and temperature